solar controller
Product Details:
| Place of Origin | Jiangsu, China |
|---|---|
| Brand Name | Shuangri |
| Model Number | SR718C |
Payment & Shipping Terms:
| Minimum Order Quantity: | 100 Set/Sets |
|---|---|
| Price: | FOB ShangHai port USD 83~135 |
| Packaging Details: | color boxes and stardard carton |
| Delivery Time: | one month |
| Payment Terms: | L/C,T/T |
| Supply Ability: | 100000 Set/Sets per Year |
Detailed Product Description
Introduce
Suitable for separated pressurized solar system
Main technical data
1. Dimension: 210mm×145mm×40mm
2. Self power consumption: <3W
3. Measuring accuracy of temperature: ±2 degree
4. Temperature range of measurement: 0--150 degree
5. Maximum power of controlled circulation pump: possible to
control 2 pumps, every power≤600W
6. Power of auxiliary electrical booster ≤2000W ( standard
collocation),≤3000W not standard,selection available
7. Inputs: 5 inputs, Pt-1000 for collector, sensor temperature
≤500 ( silicon cable ≤280), NTC10K,B=3950 for tank,
sensor temperature ≤135degree, ( PVC cable ≤105degree)
8. Outputs: 4 outputs, one for electrical booster, 2 for circulation
pump or 3-way electromagnetic valve)
9. Ambient temperature range: -10degree to 50 degree
10.Water protection grade: IP40.
2. Self power consumption: <3W
3. Measuring accuracy of temperature: ±2 degree
4. Temperature range of measurement: 0--150 degree
5. Maximum power of controlled circulation pump: possible to
control 2 pumps, every power≤600W
6. Power of auxiliary electrical booster ≤2000W ( standard
collocation),≤3000W not standard,selection available
7. Inputs: 5 inputs, Pt-1000 for collector, sensor temperature
≤500 ( silicon cable ≤280), NTC10K,B=3950 for tank,
sensor temperature ≤135degree, ( PVC cable ≤105degree)
8. Outputs: 4 outputs, one for electrical booster, 2 for circulation
pump or 3-way electromagnetic valve)
9. Ambient temperature range: -10degree to 50 degree
10.Water protection grade: IP40.
Main functions
1. Clock display
2. available systems ( 1-6 system available )
System1: 1 collector array - 1 storage tank - 1 pump
System2: 1 collector array - 2 storage tanks - 2 pumps
System3: 1 collector array - 1 storage tank - 1 pump and
back-up resource
System4: 1 collector array - 1 storage tank - 2 pumps and
hot water return heating
System5: 1 collector array - 1 storage tank - 2 pumps and
swimming pool system controlling
System6: 1 collector array - 1 storage tank - 1 pump - 1
electromagnetic valve and swimming pool
controlling
3. Speed controlling of circulation pump
4. Temperature difference on/off
5. Maximum tank temperature
6. Maximum collector temperature
7. Collector emergency cut-off
8. Limitation operation of collector at low temperature
9. Frost protection
10. Temperature controlled hot water circulation pump
11. Time controlled hot water circulation pump
12. Temperature controlled auxiliary heating during three time section
13. Holiday function
14. Thermostat of tank
15. Temperature difference adjustment of back-up boiler and heat
exchanger
16. Auto function
17. Auxiliary function/(a.Temperature difference controlling T2,
b.Heating return increasing,c.high temperature by-pass
18. Protection functions ( a. Memory protection, b. anti-bacteria
protection , c. anti- dry heating protection)
2. available systems ( 1-6 system available )
System1: 1 collector array - 1 storage tank - 1 pump
System2: 1 collector array - 2 storage tanks - 2 pumps
System3: 1 collector array - 1 storage tank - 1 pump and
back-up resource
System4: 1 collector array - 1 storage tank - 2 pumps and
hot water return heating
System5: 1 collector array - 1 storage tank - 2 pumps and
swimming pool system controlling
System6: 1 collector array - 1 storage tank - 1 pump - 1
electromagnetic valve and swimming pool
controlling
3. Speed controlling of circulation pump
4. Temperature difference on/off
5. Maximum tank temperature
6. Maximum collector temperature
7. Collector emergency cut-off
8. Limitation operation of collector at low temperature
9. Frost protection
10. Temperature controlled hot water circulation pump
11. Time controlled hot water circulation pump
12. Temperature controlled auxiliary heating during three time section
13. Holiday function
14. Thermostat of tank
15. Temperature difference adjustment of back-up boiler and heat
exchanger
16. Auto function
17. Auxiliary function/(a.Temperature difference controlling T2,
b.Heating return increasing,c.high temperature by-pass
18. Protection functions ( a. Memory protection, b. anti-bacteria
protection , c. anti- dry heating protection)
solar controller
Send your message to this supplier
Other Products from this Supplier
See more
solar controller, solar intelligent controller, solar system controller products from this supplier.
Didn't find what you're looking for? Post a buying lead.
Product Showcase[30]
Company Info
Changzhou Shuangri Electron Co., Ltd.
[China]
[Verified Member]
City: Changzhou
Province/State: Jiangsu
Country/Region : China
Business Type:Manufacturer, Trading Company, Agent
Online Postings: Products